Are you still worrying about the high difficulty to pass Microsoft certification 70-691 exam? Are you still sleeplessly endeavoring to review the book in order to pass Microsoft 70-691 exam certification? Do you want to pass Microsoft 70-691 exam certification faster? Be quick to select our DumpLeader! Having it can quickly fulfill your dreams.
Microsoft certification 70-691 exam is one of the many IT employees' most wanting to participate in the certification exams. Passing the exam needs rich knowledge and experience. While accumulating these abundant knowledge and experience needs a lot of time. Maybe you can choose some training courses or training tool and spending a certain amount of money to select a high quality training institution's training program is worthful. DumpLeader is a website which can meet the needs of many IT employees who participate in Microsoft certification 70-691 exam. DumpLeader's product is a targeted training program providing for Microsoft certification 70-691 exams, which can make you master a lot of IT professional knowledge in a short time and then let you have a good preparation for Microsoft certification 70-691 exam.
In order to protect the vital interests of each IT certification exams candidate, DumpLeader provides high-quality Microsoft 70-691 exam training materials. This exam material is specially developed according to the needs of the candidates. It is researched by the IT experts of DumpLeader. Their struggle is not just to help you pass the exam, but also in order to let you have a better tomorrow.
If you want to take Microsoft 70-691 exam, DumpLeader Microsoft 70-691 exam dumps are your best tools. The dumps can help you pass 70-691 test easily. And the dumps are very highly regarded. With our test questions and test answers, you don't need to worry about 70-691 certification. Because our dumps can solve all difficult problems you encounter in the process of preparing for the exam. Before you make a decision, you can download our free demo. For this, you will know whether our questions and answers fit to you or not.
If you are looking for a good learning site that can help you to pass the Microsoft 70-691 exam, DumpLeader is the best choice. DumpLeader will bring you state-of-the-art skills in the IT industry as well as easily pass the Microsoft 70-691 exam. We all know that this exam is tough, but it is not impossible if you want to pass it. You can choose learning tools to pass the exam. I suggest you choose DumpLeader Microsoft 70-691 exam questions and answers. I suggest you choose DumpLeader Microsoft 70-691 exam questions and answers. The training not only complete but real wide coverage. The test questions have high degree of simulation. This is the result of many exam practice. . If you want to participate in the Microsoft 70-691 exam, then select the DumpLeader, this is absolutely right choice.
Exam Code: 70-691
Exam Name: Microsoft (TS: Windows HPC Server 2008, Developing)
One year free update, No help, Full refund!
Total Q&A: 95 Questions and Answers
Last Update: 2014-01-14
Are you still worrying about how to safely pass Microsoft certification 70-691 exams? Do you have thought to select a specific training? Choosing a good training can effectively help you quickly consolidate a lot of IT knowledge, so you can be well ready for Microsoft certification 70-691 exam. DumpLeader's expert team used their experience and knowledge unremitting efforts to do research of the previous years exam, and finally have developed the best pertinence training program about Microsoft certification 70-691 exam. Our training program can effectively help you have a good preparation for Microsoft certification 70-691 exam. DumpLeader's training program will be your best choice.
In this era, everything is on the rise. Do not you want to break you own? Double your salary, which is not impossible. Through the Microsoft 70-691 exam, you will get what you want. DumpLeader will provide you with the best training materials, and make you pass the exam and get the certification. It's a marvel that the pass rate can achieve 100%. This is indeed true, no doubt, do not consider, act now.
70-691 Free Demo Download: http://www.dumpleader.com/70-691_exam.html
NO.1 if(commRank == 0) {
NO.2 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
The application uses point-to-point communication.
The process that has a rank 0 sends an array of integer values to the rank 1 process by using the
following code segment. (Line numbers are included for reference only.)
01 int values[5];
02 MPI_Send(values, 5, MPI_INT, 1, 42,
03 MPI_COMM_WORLD);
You need to ensure that each receiving process is able to correctly receive the values in the most efficient
manner possible.
Which code segment should you use?
A. int values[5];
int buffer[5];
MPI_Reduce(buffer, values, 5, MPI_INT, MPI_SUM, 1, MPI_COMM_WORLD);
B. int values[5];
MPI_Status status;
MPI_Recv(values, 5, MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
C. int value;
MPI_Status status;
MPI_Recv(&value, 1, MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
D. int values[5];
MPI_Status status;
MPI_Recv(values, sizeof(int), MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
Answer: B
Microsoft exam dumps 70-691 70-691 70-691 braindump
NO.3 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment. (Line numbers are included for reference only.)
01 int rank;
02 MPI_Comm_rank(MPI_COMM_WORLD, &rank);
03 // declaration of variable hostName
04 // code to execute
05
06 std::cout << "hostname of rank " << rank;
07 std::cout << ": " << hostName << "\n";
You need to ensure that a variable named hostName contains the name of the cluster node that the code
runs on.
Which code segment should you add at line 05?
A. char *hostName = getenv("MPI_HOSTNAME");
B. char hostName[MPI_MAX_PROCESSOR_NAME];
int resultlen;
MPI_Get_processor_name(&resultlen, hostName);
C. char hostName[MPI_MAX_NAME_STRING];
int resultlen;
MPI_Comm_get_name(MPI_COMM_WORLD, hostName, &resultlen);
D. char hostName[256];
int resultlen = sizeof(hostName);
if (rank == 0)
{
gethostname(hostName, resultlen);
}
Answer: B
Microsoft 70-691 braindump 70-691 exam simulations 70-691 70-691 70-691
NO.4 You plan to develop a parallel application by using Windows HPC Server 2008.
You plan to use a method to control the calculations performed by each individual process.
You need to ensure that different commands can be sent to each process.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: A
Microsoft 70-691 70-691 certification training 70-691 exam prep 70-691 exam dumps
NO.5 You plan to develop a single program multiple data (SPMD) application by using Windows HPC Server
2008.
You use multiple processes to perform intermediate calculations and to provide the results as a single
number.
You need to ensure that the intermediate results are collected and added together by using a single MPI
function.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: D
Microsoft exam dumps 70-691 70-691 70-691 exam Braindumps 70-691
NO.6 pi = 4 * total/(commSize * totDarts);
NO.7 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment that computes an approximation to Pi. (Line numbers are included
for reference only.)
01 static int totDarts = 10000;
02 int numDarts = 0;
03
04 MPI_Comm_size(MPI_COMM_WORLD, &commSize);
05 MPI_Comm_rank(MPI_COMM_WORLD, &commRank);
06
07 for(i = 0; i < totDarts; i++) {
08 x = 2 * (randomNr() - 0.5);
09 y = 2 * (randomNr() - 0.5);
NO.8 You plan to develop a parallel application by using Windows HPC Server 2008.
You need to ensure that when the application starts, a parameter value is communicated to each process
in the cluster by using a single call.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: B
Microsoft exam 70-691 70-691 70-691 test questions
NO.9 You plan to develop a parallel application by using Windows HPC Server 2008.
You need to implement a method that will send different data to each process in a communicator by using
a single call.
Which function should you use?
A. MPI_Send
B. MPI_Gather
C. MPI_Reduce
D. MPI_Scatter
Answer: D
Microsoft test questions 70-691 70-691 70-691 70-691 test questions
NO.10 You plan to develop a parallel application by using Windows HPC Server 2008.
The application performs the following tasks:
x Performs multistep calculations
x Processes data by using the same code segment that runs on each compute node
You need to ensure that each compute process executes the same step simultaneously.
Which type of communication should you use?
A. Buffered
B. Collective
C. Non-blocking
D. Point-to-point
Answer: B
Microsoft 70-691 Bootcamp 70-691 practice test 70-691 70-691 questions
NO.11 if (x*x + y*y <= 1.0)
NO.12 }
You need to ensure that the total number of numDarts is only available on the process that has a rank 0.
Which code segment should you insert at line 13?
A. MPI_Reduce(&numDarts, &total, 1, MPI_INT, MPI_SUM, 0, MPI_COMM_WORLD)
B. MPI_Allreduce(&total, &numDarts, 1, MPI_INT, MPI_SUM, MPI_COMM_WORLD)
C. MPI_Gather(&numDarts, 1, MPI_INT, &total, 1, MPI_INT, 0, MPI_COMM_WORLD)
D. MPI_Allgather(&numDarts, 1, MPI_INT, &total, 1, MPI_INT, MPI_COMM_WORLD)
Answer: A
Microsoft test answers 70-691 70-691
10. You plan to develop a Microsoft Message Passing Interface (MPI) application by using Microsoft
Visual Studio.
You have installed the Microsoft HPC Pack 2008 SDK at C:\Program Files\Microsoft HPC Pack 2008
SDK.
You create a new console application.
You need to ensure that the application compiles for a 64-bit architecture.
Which two tasks should you perform? (Each correct answer presents part of the solution. Choose two.)
A. Set the Import Library property to msmpi.lib.
B. Set the Additional Dependencies property to msmpi.lib.
C. Set the Additional Library Directories property to C:\Program Files\Microsoft HPC Pack 2008
SDK\lib\amd64.
D. Set the Additional Manifest Dependencies property to C:\Program Files\Microsoft HPC Pack 2008
SDK\lib\amd64.
Answer: BC
Microsoft 70-691 answers real questions 70-691 70-691
11. You develop a parallel application by using Microsoft Visual Studio 2008.
You have installed the Microsoft HPC Pack 2008 SDK at C:\Program Files\Microsoft HPC Pack 2008
SDK.
You create a new console application based on Microsoft Message Passing Interface (MPI). You set the
Debugger to Launch property to MPI Cluster Debugger.
You need to ensure that five processes are launched when the application is run in debug mode in Visual
Studio 2008.
Which two tasks should you perform? (Each correct answer presents part of the solution. Choose two.)
A. Set the MPIRun Arguments property to -n 5.
B. Set the Application Arguments property to -n 5.
C. Set the MPIRun Working Directory property to C:\Program Files\Microsoft HPC Pack 2008 SDK\bin.
D. Set the MPIRun Command property to C:\Program Files\Microsoft HPC Pack 2008 SDK\bin\MPIExec.
E. Set the Application Command property to C:\Program Files\Microsoft HPC Pack 2008
SDK\bin\MPIExec.
Answer: AD
Microsoft pdf 70-691 70-691 70-691 70-691
12. You create a parallel application by using Microsoft Visual Studio 2008.
The application prints a message to the console of all Microsoft Message Passing Interface (MPI)
processes except for one. The application terminates and displays an error message.
You need to change the code in the application so that the application completes successfully.
Which set of tasks should you include in the application?
A. Include mpi.h
Link to msmpi.lib
Call MPI_Start
Call MPI_Comm_rank
Call MPI_Finalize
B. Include mpi.h
Link to msmpi.lib
Call MPI_Init
Call MPI_Comm_rank
Call MPI_Finalize
C. Include mpi.h
Link to ccpapi.tlb
Call MPI_Init
Call MPI_Comm_rank
D. Include mpi.h
Link to msmpi.lib
Call MPI_Init
Call MPI_Comm_size
Answer: B
Microsoft test questions 70-691 70-691 answers real questions
13. You plan to create a parallel application by using Microsoft Visual C++.
You want to use the Microsoft Message Passing Interface (MPI) library in the application.
You need to ensure that the application can be compiled for both 32-bit and 64-bit platforms. You also
need to ensure that targeting both platforms requires minimum maintenance.
What should you do?
A. Create a separate project for each platform.
B. Create separate solution files for each platform.
C. Create separate custom build rules for each platform.
D. Create a separate build configuration for each platform.
Answer: D
Microsoft 70-691 practice questions 70-691 demo 70-691 test
14. You create a Microsoft Message Passing Interface (MPI) application by using Microsoft Visual Studio
2008.
The application process is named MPIApplication.exe. You plan to debug the application by using the MPI
Cluster Debugger in Visual Studio 2008.
You need to attach the debugger to the remote process on a compute node.
Which process should you attach to?
A. smpd.exe
B. mpiexec.exe
C. msvmon.exe
D. MPIApplication.exe
Answer: C
Microsoft 70-691 answers real questions 70-691 70-691 70-691 questions 70-691
15. You create a Microsoft Message Passing Interface (MPI) application by using Microsoft Visual Studio
2008.
You plan to debug the application by using Visual Studio 2008.
You need to configure the nodes that will be used for debugging.
What should you do?
A. Use the Cluster Debugger Configuration tool in Visual Studio.
B. Use the debugging pane in the Visual Studio project property pages.
C. Use the configuration pane in the Cluster Administration Console tool.
D. Use the node management pane in the Cluster Administration Console tool.
Answer: A
Microsoft 70-691 70-691 study guide 70-691 braindump
NO.13 }
NO.14
NO.15 ++numDarts;
NO.16 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment. (Line numbers are included for reference only.)
01 MPI_Init(&argc, &argv);
02
03 {
04 // program part for rank 0
05
06 }
06 else
07 {
08 // program part for all other ranks
09 }
10 MPI_Finalize();
You need to ensure that the code in the rank 0 section only executes on the process that has a rank of 0.
Which code segment should you insert at line 02?
A. int size;
MPI_Comm_size(MPI_COMM_WORLD, &size);
if (size > 0)
B. int size;
MPI_Comm_size(MPI_COMM_WORLD, &size);
if (size == 0)
C. int rank
MPI_Comm_rank(MPI_COMM_WORLD, &rank);
if (rank == 0)
D. char hostName[MPI_MAX_PROCESSOR_NAME];
int resultlen;
MPI_Get_processor_name(hostName, &resultlen);
char masterName[] = "rank0";
if (strcmp(masterName, hostName) != 0)
Answer: C
Microsoft questions 70-691 70-691 certification 70-691 original questions
NO.17 printf("Pi = %d\n", pi);
DumpLeader offer the latest 642-447 exam material and high-quality 74-353 pdf questions & answers. Our HP2-N35 VCE testing engine and 400-051 study guide can help you pass the real exam. High-quality HP3-C33 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.dumpleader.com/70-691_exam.html
没有评论: